Saturday, January 5, 2008

RE: Handrail Loads vs Short Term

Harold, Dr. Hamida, engineers,



It seems like the most significant place a one-third
allowable stress increase is still permitted is when designing footings with
the appropriate load combinations. I'm
looking at footnote d on table 1804.2 of the 2006 IBC which specifies "allowable
foundation pressure" and "lateral bearing pressure."



On the other hand, there is the requirement for a soil
investigation in section 1802 for anything in seismic design class C or
higher. An investigation could trump
table 1804.2 and the one-third increase.
Is that right?



thanks,
Mark Johnson

******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
*

http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org

******* ****** ****** ****** ******* ****** ****** ********