From: bill@polhemus.cc [mailto:bill@polhemus.cc]
Sent: Friday, February 20, 2009 11:05 AM
To: seaint@seaint.org
Subject: Re: ASCE 7-05: RSA Procedure per 12.9
>> ...The result should be
>> compared to the equivalent lateral force base shear and only
increased
>> if it is below 85% of that value -- you cannot scale it down.
That is correct. Thanks.