From: h.d.richardson <h.d.richardson@telus.net>
To: seaint@seaint.org
Sent: Sunday, December 25, 2011 2:34 AM
Subject: Season's Greetings
On 12/23/2011 10:40 AM, Kembcon wrote:
> --------------------------------------------------------------------------
>
> This message is too long to be posted to this list.
> --------------------------------------------------------------------------
>
>
>
> So, start a new list already. I don't know why your system garbles
> messages so badly and inserts so much gibberish.
>
> If you'd clean up your lists, the posts would be much shorter. Why is
> it necessary to recapitulate all the previous posts in each message?
>
> / eric
>
> On 12/23/2011 9:43 AM, Kembcon wrote:
>> --------------------------------------------------------------------------
>>
>> This message is too long to be posted to this list.
>> --------------------------------------------------------------------------
>>
>>
>>
>> I know Mark's building. The walls were tilted and braced, then the
>> pilasters were field cast around the exposed rebar from the sides of
>> the wall panels. The pilasters take the vertical loads from the roof
>> trusses and, Mark Argues, take the lateral load from the wall panels
>> as well.
>>
>> The pilasters are 24 feet on center and are fixed to some degree at
>> the bottoms, but the foundations are not sized to resist any
>> significant moment from the pilasters.
>>
>> The ledger height at the walls is 18', so the wall panels span 18'
>> vertically and, mark argues, 22' horizontally.
>>
>> Mark argues, I think, that since the roof diaphragm is flexible of
>> semi-flexible, at best, the pilasters must somehow resist the lateral
>> loads from the walls (and roof structure?). He is skeptical, if I
>> understand his argument, that the wood/plywood diaphragm is able to
>> span horizontally between the concrete walls at each end of the
>> building, parallel to the roof trusses.
>>
>> I think his objection is to the whole concept of Rigid Wall /
>> Flexible Diaphragm buildings, which do indeed have many weak links,
>> particularly those from the fifties and sixties, but I'll let him
>> repond for himslf.
>>
>> Merry Christmas, everyone! / eric
>>
>>
>>
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
| Will, I assumed that the panels were keyed in to the pilasters, but maybe not huh. So, I guess there's that to think about too. Thanks for the comment. Mark --- On Thu, 12/22/11, William Haynes <gtg740p@gmail.com> wrote:
|
This is a question about how concrete panels in a tiltup building resist out-of-plane loads. Do they span horizontally between pilasters or span vertically between the diaphragm and the floor slab.
A colleague and I are looking an existing tiltup with 6" thick panels, elevated floor slab at 3' above grade and pilasters at 24" o.c. There is an arched wood diaphragm, 220' x 116'. The diaphragm is supported by bow string trusses, 18' above the floor slab and supported by the pilasters every 24' and spanning the 116' direction. The pilasters are braced out-of-plane by the trusses and the diaphragm.
The owner wants to cut some new roll-up door openings in some panels and fill in others with CMU or shotcreet.
And, oh yeah, the building is in seismic design category D.
The arched diaphragm slopes about 1:3 and doesn't have sub-diaphragms (it's an old building).
One question will determine how to reinforce the panels at the new openings.
Plan A is to assume that the panels span vertically and that the diaphragm is stiff enough support the panels out-of-plane, even in between the pilasters. Therefore, it is only necessary to reinforce with a HSS section over the new opening and attach it to the panel at the edge of the opening, not all the way over to the pilasters. Or to run two HSS sections vertically at the sides of the new openings spanning from bottom to just under the diaphragm in between the pilasters.
Plan B is to assume that the panels span horizontally between pilasters and reinforce with an HSS above the new openings spanning the full distance between pilasters and thru-bolted to the walls just above the openings. Although the panels attach to the diaphragm in between the pilasters, the assumption is that there is nothing in the diaphragm in between the pilasters (probably plywood or 1x sheathing) which would offer any significant out-of-plane resistance to the panels because the trusses only occur at the pilasters.
Another subject of discussion is whether to recreate the stiffness in the original concrete panels with the HSS reinforcement or just to recreate the strength required by the out-of-plane forces.
TIA,
Mark Johnson
This is a question about how concrete panels in a tiltup building resist out-of-plane loads. Do they span horizontally between pilasters or span vertically between the diaphragm and the floor slab.
| This is a question about how concrete panels in a tiltup building resist out-of-plane loads. Do they span horizontally between pilasters or span vertically between the diaphragm and the floor slab.
A colleague and I are looking an existing tiltup with 6" thick panels, elevated floor slab at 3' above grade and pilasters at 24" o.c. There is an arched wood diaphragm, 220' x 116'. The diaphragm is supported by bow string trusses, 18' above the floor slab and supported by the pilasters every 24' and spanning the 116' direction. The pilasters are braced out-of-plane by the trusses and the diaphragm.
The owner wants to cut some new roll-up door openings in some panels and fill in others with CMU or shotcreet.
And, oh yeah, the building is in seismic design category D.
The arched diaphragm slopes about 1:3 and doesn't have sub-diaphragms (it's an old building).
One question will determine how to reinforce the panels at the new openings.
Plan A is to assume that the panels span vertically and that the diaphragm is stiff enough support the panels out-of-plane, even in between the pilasters. Therefore, it is only necessary to reinforce with a HSS section over the new opening and attach it to the panel at the edge of the opening, not all the way over to the pilasters. Or to run two HSS sections vertically at the sides of the new openings spanning from bottom to just under the diaphragm in between the pilasters.
Plan B is to assume that the panels span horizontally between pilasters and reinforce with an HSS above the new openings spanning the full distance between pilasters and thru-bolted to the walls just above the openings. Although the panels attach to the diaphragm in between the pilasters, the assumption is that there is nothing in the diaphragm in between the pilasters (probably plywood or 1x sheathing) which would offer any significant out-of-plane resistance to the panels because the trusses only occur at the pilasters.
Another subject of discussion is whether to recreate the stiffness in the original concrete panels with the HSS reinforcement or just to recreate the strength required by the out-of-plane forces.
TIA, Mark Johnson |
Gary,
I am not sure if ASCE or similar Canadian codes have a specific
opinion or load combination for this. But I would think that the
probability of planes taking off during a significant wind would be
quite low if not impossible. I think in absence of other requirements
I would check it 2 different ways:
Full wind pressure
Full plane pressure + wind pressure at max wind speed allowed for
plane takeoffs/landings (maybe available from FAA or the Canadian
equivalent)
However, a quick google search seemed to indicate large commercial
planes can be landed in 50-60+ knots... And they said there is no
established speed, like everything else, it depends...
Regards,
Andrew Kester, PE
Florida
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
However, a quick google search seemed to indicate large commercial
planes can be landed in 50-60+ knots... And they said there is no
established speed, like everything else, it depends...
Regards,
Andrew Kester, PE
Florida
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
Bill,
Just so it is clear, I was not referring to you...both because you were not asking for it to be free (which was clear from your previous messages) and because I believe that you have some justification to your complaint about onerous copy protection schemes (it annoys the crap out of me that I get treated like a criminal just because a bunch of other people have chosen to use stuff they don't pay for while I have paid for my codes...and movies and music, etc).
About the only way that I was maybe referring to you was your penchant for running wild with any opportunity for going off topic with politics. <grin>
Regards,
Scott
On Dec 21, 2011, at 12:47 AM, Bill Polhemus wrote:
> No one disputes the fact that nothing is free - unless, apparently, you're an "Occupy Wall Street" type.
>
> My POINT is simply that this was a p*ss-poor example of value received. My opinion, period, and you are free to disagree.
>
> If ACI wants to charge me the same to read a document on a computer screen as they charge someone who purchases the PDF from their website - and in so doing allows them to copy-and-paste content from it, print a hard-copy, etc, which I'm not allowed - then they have every right to do so.
>
> But I have the equal right to complain as a consumer. Simple as that.
>
> And might I say in passing, that it would be great if the People would begin to demand the same level of goods and services of all levels of government for what we pay, as we do business.
>
> But complaints like that are taken to be "radical" and "extreme". Can you imagine the hilarity that would ensue if bank officers told us to stop demanding a reduction in all the niggling fees they charge, the way that certain political factions react in (feigned) horror that politicians agree to sign a pledge not to raise taxes?
>
> William L. Polhemus, Jr. P.E.
> Sent from my iPhone 4
>
> On Dec 20, 2011, at 9:27 PM, Scott Maxwell <smaxwell@umich.edu> wrote:
>
>> And, of course, nothing the "government" does is actually free...there is that pesky thing called taxes that no one ever likes to pay...but they still want the stuff from the "government".
>>
>> Sorry if that creates a political $hit storm...it is not in ANYWAY meant to be a political statement but rather a remind of all those fans of "free stuff" that is still takes money to produce those documents...
>
> ******* ****** ******* ******** ******* ******* ******* ***
> * Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> *
> * This email was sent to you via Structural Engineers
> * Association of Southern California (SEAOSC) server. To
> * subscribe (no fee) or UnSubscribe, please go to:
> *
> * http://www.seaint.org/sealist1.asp
> *
> * Questions to seaint-ad@seaint.org. Remember, any email you
> * send to the list is public domain and may be re-posted
> * without your permission. Make sure you visit our web
> * site at: http://www.seaint.org
> ******* ****** ****** ****** ******* ****** ****** ********
>
>
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
Just so it is clear, I was not referring to you...both because you were not asking for it to be free (which was clear from your previous messages) and because I believe that you have some justification to your complaint about onerous copy protection schemes (it annoys the crap out of me that I get treated like a criminal just because a bunch of other people have chosen to use stuff they don't pay for while I have paid for my codes...and movies and music, etc).
About the only way that I was maybe referring to you was your penchant for running wild with any opportunity for going off topic with politics. <grin>
Regards,
Scott
On Dec 21, 2011, at 12:47 AM, Bill Polhemus wrote:
> No one disputes the fact that nothing is free - unless, apparently, you're an "Occupy Wall Street" type.
>
> My POINT is simply that this was a p*ss-poor example of value received. My opinion, period, and you are free to disagree.
>
> If ACI wants to charge me the same to read a document on a computer screen as they charge someone who purchases the PDF from their website - and in so doing allows them to copy-and-paste content from it, print a hard-copy, etc, which I'm not allowed - then they have every right to do so.
>
> But I have the equal right to complain as a consumer. Simple as that.
>
> And might I say in passing, that it would be great if the People would begin to demand the same level of goods and services of all levels of government for what we pay, as we do business.
>
> But complaints like that are taken to be "radical" and "extreme". Can you imagine the hilarity that would ensue if bank officers told us to stop demanding a reduction in all the niggling fees they charge, the way that certain political factions react in (feigned) horror that politicians agree to sign a pledge not to raise taxes?
>
> William L. Polhemus, Jr. P.E.
> Sent from my iPhone 4
>
> On Dec 20, 2011, at 9:27 PM, Scott Maxwell <smaxwell@umich.edu> wrote:
>
>> And, of course, nothing the "government" does is actually free...there is that pesky thing called taxes that no one ever likes to pay...but they still want the stuff from the "government".
>>
>> Sorry if that creates a political $hit storm...it is not in ANYWAY meant to be a political statement but rather a remind of all those fans of "free stuff" that is still takes money to produce those documents...
>
> ******* ****** ******* ******** ******* ******* ******* ***
> * Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> *
> * This email was sent to you via Structural Engineers
> * Association of Southern California (SEAOSC) server. To
> * subscribe (no fee) or UnSubscribe, please go to:
> *
> * http://www.seaint.org/sealist1.asp
> *
> * Questions to seaint-ad@seaint.org. Remember, any email you
> * send to the list is public domain and may be re-posted
> * without your permission. Make sure you visit our web
> * site at: http://www.seaint.org
> ******* ****** ****** ****** ******* ****** ****** ********
>
>
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
And, of course, nothing the "government" does is actually free...there is that pesky thing called taxes that no one ever likes to pay...but they still want the stuff from the "government".Sorry if that creates a political $hit storm...it is not in ANYWAY meant to be a political statement but rather a remind of all those fans of "free stuff" that is still takes money to produce those documents...yes, even when it is organization members doing most of the work unpaid. Paid staff still need to a LOT of work to produce the likes of ACI 318, the MSJC, ASCE 7, and every other document.Sorry...but the "everything should be free" constantly re-occuring argument just annoys me. I take someone who makes that argument serious when they offer their engineering services for free...or at least offer it for the cost of paper their contact documents is printed on.As the real subject at hand, I agree that PDF and other "eDocuments" are getting more and more bogged down with copy protection crap that limits their usefulness. I was little annoyed with the new PDF version of the NDS. The previous version was great as it would work with ANY PDF program. The current version HAS to be used with Adobe Acrobat only...and Acrobat Reader on the Mac is a dog. I much prefer Preview. But, I will admit that it is not as locked down as it seems ACI's documents are (Jay you might want to contact the folks at AF&PA/AWC to see what copy protection system they use and pass that info on to the powers that be at ACI...but they might already be aware of it).Regards,ScottOn Dec 15, 2011, at 4:41 PM, Jay Shilstone wrote:
FYI, I understand comments from others that documents relating to the Building Code ought to be free. As I understand it, in countries where codes are created by bureaucrats, that is the case. However, ACI and ASTM are not government organizations. I know ACI doesn't receive government funding, but don't know about ASTM. Our codes are created as consensus documents by independent organizations. Even if those organizations are non-profit, it doesn't mean they don't need to bring in money to survive. I think it is a case of, "Do we want free documents created by government committees or do we want documents based on field experience that we have to pay for?" There is no "right" answer, but the reality is that this is the system that we use in the U.S.
My POINT is simply that this was a p*ss-poor example of value received. My opinion, period, and you are free to disagree.
If ACI wants to charge me the same to read a document on a computer screen as they charge someone who purchases the PDF from their website - and in so doing allows them to copy-and-paste content from it, print a hard-copy, etc, which I'm not allowed - then they have every right to do so.
But I have the equal right to complain as a consumer. Simple as that.
And might I say in passing, that it would be great if the People would begin to demand the same level of goods and services of all levels of government for what we pay, as we do business.
But complaints like that are taken to be "radical" and "extreme". Can you imagine the hilarity that would ensue if bank officers told us to stop demanding a reduction in all the niggling fees they charge, the way that certain political factions react in (feigned) horror that politicians agree to sign a pledge not to raise taxes?
William L. Polhemus, Jr. P.E.
Sent from my iPhone 4
On Dec 20, 2011, at 9:27 PM, Scott Maxwell <smaxwell@umich.edu> wrote:
> And, of course, nothing the "government" does is actually free...there is that pesky thing called taxes that no one ever likes to pay...but they still want the stuff from the "government".
>
> Sorry if that creates a political $hit storm...it is not in ANYWAY meant to be a political statement but rather a remind of all those fans of "free stuff" that is still takes money to produce those documents...
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
William L. Polhemus, Jr. P.E.
Sent from my iPhone 4
On Dec 20, 2011, at 7:32 PM, Mark Benjamin <mark@crownjade.com> wrote:
> I have always said that concrete guys don't have 1/2" on their tapes.
>
> "bill@polhemus.cc" <bill@polhemus.cc> wrote:
>
>> Here's a question I THOUGHT I knew the answer to...but for the life of me I
>> can't locate it any longer if it ever existed.
>>
>> What defines the standard for concrete drafting precision?
>>
>> I know that ACI 117 is about the as-constructed tolerance for concrete elements,
>> but what about what is put on the drawings to begin with?
>>
>> For instance, is it reasonable to show a spread footing foundation to the 1/16th
>> of an inch, as recently came across my desk? I thought I remembered that there
>> were specific precision allowances for different elements - for instance, to the
>> half-inch, or the the nearest inch, etc.
>>
>> Where is that found? Or is it?
>>
>> Sorry, my mind is going. I can feel it.E杖+-�m����j)�?�+-���Ǧj)pj���hʋ������-���x"�竰,�Ț�*'���^�p��'�x�H@H+��N�.n�+�����'J��r��z�^jǠ��!���0�梞�+��jX��V����ب��h�梞֝�梞�+��zfޭ��zf��*.��ݶ�azX��+)��bq�&j)ڝٚɷ�z�,��p��h�ܨ��^�h��*'1����ʋ��ȭ���y�"�歆�i��0�ǚ�{h�
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
FYI, I understand comments from others that documents relating to the Building Code ought to be free. As I understand it, in countries where codes are created by bureaucrats, that is the case. However, ACI and ASTM are not government organizations. I know ACI doesn't receive government funding, but don't know about ASTM. Our codes are created as consensus documents by independent organizations. Even if those organizations are non-profit, it doesn't mean they don't need to bring in money to survive. I think it is a case of, "Do we want free documents created by government committees or do we want documents based on field experience that we have to pay for?" There is no "right" answer, but the reality is that this is the system that we use in the U.S.
Here's a question I THOUGHT I knew the answer to...but for the life of me I can't locate it any longer if it ever existed.
What defines the standard for concrete drafting precision?
I know that ACI 117 is about the as-constructed tolerance for concrete elements, but what about what is put on the drawings to begin with?
For instance, is it reasonable to show a spread footing foundation to the 1/16th of an inch, as recently came across my desk? I thought I remembered that there were specific precision allowances for different elements - for instance, to the half-inch, or the the nearest inch, etc.
Where is that found? Or is it?
Sorry, my mind is going. I can feel it.
http://www.us.hilti.com/holus/page/module/product/prca_rangedetail.jsf?lang=en&nodeId=-72689
If the drawings call out the bar size, a Profometer (Pachometer) can accurately establish the cover.
Contact your local WJE office, they have skilled personnel that know how to operate the equipment.
D. Matthew Stuart, P.E., S.E., F.ASCE, SECB
Structural Division ManagerPennoni Associates Inc. One Drexel Plaza
3001 Market Street, 2 nd Floor
Philadelphia, PA 19104
Office 215-222-3000 x7895 | Direct 215-254-7895
Fax 215-222-0789 | Mobile 908-309-8657
http://www.pennoni.com | mstuart@pennoni.com
From: Joseph Goldbronn [mailto:jgoldbronn@hscgi.com]
Sent: Monday, December 19, 2011 6:13 PM
To: seaint@seaint.org
Subject: Determining Existing Reinforcement Depth
I have a situation where I would like to determine the depth of existing reinforcement in a slab. The existing plans that I have do not clearly state the concrete coverage and I have talked to both the architect and owner and neither has more information other than what they gave to me as as-builts. The problem that I am having is that a new, more powerful MRI is being installed with more stringent requirement of how much steel is allowed in the floor at segmented depths. The contractor would prefer not to rip the floor including the RF shield on the floor and I was wondering if there was a way to determine the depth of steel in the floor. I have no experience with x-ray, GPR, etc. and do not know if they would work in determining depths or even how accurate the reading will be.
Joe G.
I'm designing a sound-barrier wall for an airport. The specifications
list a basic wind pressure and a jet-blast loading pressure without
saying whether these are additive or not. I've asked for clarification
but haven't received an answer and I don't know whether they have the
knowledge determine in what proportions to combine the two loadings.
Has anybody had any experience in this area?
Gary
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********
If the drawings call out the bar size, a Profometer (Pachometer) can accurately establish the cover.
Contact your local WJE office, they have skilled personnel that know how to operate the equipment.
D. Matthew Stuart, P.E., S.E., F.ASCE, SECB
Structural Division Manager
Pennoni Associates Inc.
One Drexel Plaza
3001 Market Street, 2nd Floor
Philadelphia, PA 19104
Office 215-222-3000 x7895 | Direct 215-254-7895
Fax 215-222-0789 | Mobile 908-309-8657
http://www.pennoni.com | mstuart@pennoni.com
From: Joseph Goldbronn [mailto:jgoldbronn@hscgi.com]
Sent: Monday, December 19, 2011 6:13 PM
To: seaint@seaint.org
Subject: Determining Existing Reinforcement Depth
I have a situation where I would like to determine the depth of existing reinforcement in a slab. The existing plans that I have do not clearly state the concrete coverage and I have talked to both the architect and owner and neither has more information other than what they gave to me as as-builts. The problem that I am having is that a new, more powerful MRI is being installed with more stringent requirement of how much steel is allowed in the floor at segmented depths. The contractor would prefer not to rip the floor including the RF shield on the floor and I was wondering if there was a way to determine the depth of steel in the floor. I have no experience with x-ray, GPR, etc. and do not know if they would work in determining depths or even how accurate the reading will be.
Joe G.
I have a situation where I would like to determine the depth of existing reinforcement in a slab. The existing plans that I have do not clearly state the concrete coverage and I have talked to both the architect and owner and neither has more information other than what they gave to me as as-builts. The problem that I am having is that a new, more powerful MRI is being installed with more stringent requirement of how much steel is allowed in the floor at segmented depths. The contractor would prefer not to rip the floor including the RF shield on the floor and I was wondering if there was a way to determine the depth of steel in the floor. I have no experience with x-ray, GPR, etc. and do not know if they would work in determining depths or even how accurate the reading will be.
Joe G.