table R602.3.1, you can use a 2x4 s.pine stud for walls up to 12' tall
in 100 mph, exposure C, with building heights exceeding 25' (C&C, zone
4, EWA=50, 17.6psf with lambda=1.35)? That, of course, presumes that a
contractor and AHJ knows what an E=1.6x10^6 even means, and doesn't
substitute Hem-Fir or SPF.
Yes, I'm in a bad mood this Monday.
Jordan
Mark Deardorff wrote:
> I would stick with L/600. What difference whether it is wood or steel would
> it make? The L/600 is based on the need to maintain integrity of the veneer.
>
>
>
>
******* ****** ******* ******** ******* ******* ******* ***