Thursday, August 2, 2007

Re: Glu-Lam beam with Steel Channel calc


Erik,

If you can insure that both beams will be loaded simultaneously then each beam will take the applied load in proportion to their stiffness.

Thomas Hunt, S.E.
Fluor



"erik gibbs" <erik.gibbs@gmail.com>
08/02/2007 10:58 AM
Please respond to seaint
To
seaint@seaint.org
cc
Subject
Glu-Lam beam with Steel Channel calc





I previously posted a question about a plan check question for out of plane loading on a shearwall and to all that posted I thank you, it cleared up any questions that I had.
 
Now to my new question. I have an existing 5-1/8" x 15"  Glu Lam beam that spans 21'-6" in a garage of an existing residence. The owner wants to turn this into a flush beam, which means taking a few laminations off and sistering a new beam next to the GLB. I want to use a steel channel, C10x15.3, but this section, when checked in bending fails under the full load. Also the GLB fails under the full load when checked by itself. My question is how would you check/calc both beams in a rational method, instead of just saying that the GLB takes 50% of the load and the steel beam takes the other 50%?
 
Thanks
 
Erik Gibbs
 
------------------------------------------------------------ The information transmitted is intended only for the person  or entity to which it is addressed and may contain  proprietary, business-confidential and/or privileged material.   If you are not the intended recipient of this message you are  hereby notified that any use, review, retransmission, dissemination,  distribution, reproduction or any action taken in reliance upon  this message is prohibited. If you received this in error, please  contact the sender and delete the material from any computer.    Any views expressed in this message are those of the individual  sender and may not necessarily reflect the views of the company.   ------------------------------------------------------------