Your geo-tech guy who is checking the capacities should also be giving you the minimum spacing.

Thomas Hunt, S.E.
Fluor



"Micayas, Julius" <jmicayas@riverconsulting.com>
09/12/2007 12:52 PM
Please respond to seaint
To
<seaint@seaint.org>
cc
Subject
RE: Spacing for 36" dia. hollow steel pile





Unfortunately, this is an expansion project that Geo-tech report on file does not have that kind of info. Currently, we have a geo-tech guy checking the capacity for both vertical and lateral forces.
 
Julius Micayas
River Consulting
 



From: Tom.Hunt@fluor.com [mailto:Tom.Hunt@fluor.com]
Sent:
Wednesday, September 12, 2007 2:45 PM
To:
seaint@seaint.org
Subject:
Re: Spacing for 36" dia. hollow steel pile

 

Julius,


For an offshore application you probably should being using the recommendations from a properly written site specific geotechnical reports which should provide you with all the parameters for your pile design including vertical/horizontal capacities, minimum spacing, moment vs shear diagrams, group effects for downdrag, etc.


Thomas Hunt, S.E.

Fluor


  "Micayas, Julius" <jmicayas@riverconsulting.com>
09/12/2007 12:18 PM

Please respond to seaint

To
<seaint@seaint.org>
cc
 
Subject
Spacing for 36" dia. hollow steel pile

 


   





Gents:

 
I am using 36" diameter hollow steel piles for my off-shore application; my pile cap requires
A total of 18 piles (i.e. 6 each row) going with the rule of thumb 3 x pile diameter, I ended up 9' center

which will give me  a wider width.
 
Is there a code that specifies the min. spacing of piles?

 
Thanks,

 
Engr. Julius Micayas

P.E. license no.32969

Senior Lead Structural Engineer

 
Phone - 504-841-3014 (direct)

504 837-5275 (office)

Fax - 504-837-2986

 
E-mail:            jmicayas@riverconsulting.com

 

------------------------------------------------------------
The information transmitted is intended only for the person
or entity to which it is addressed and may contain
proprietary, business-confidential and/or privileged material.  
If you are not the intended recipient of this message you are
hereby notified that any use, review, retransmission, dissemination,
distribution, reproduction or any action taken in reliance upon
this message is prohibited. If you received this in error, please
contact the sender and delete the material from any computer.  
 
Any views expressed in this message are those of the individual
sender and may not necessarily reflect the views of the company.  
------------------------------------------------------------
------------------------------------------------------------ The information transmitted is intended only for the person  or entity to which it is addressed and may contain  proprietary, business-confidential and/or privileged material.   If you are not the intended recipient of this message you are  hereby notified that any use, review, retransmission, dissemination,  distribution, reproduction or any action taken in reliance upon  this message is prohibited. If you received this in error, please  contact the sender and delete the material from any computer.    Any views expressed in this message are those of the individual  sender and may not necessarily reflect the views of the company.   ------------------------------------------------------------