learned anything, but interesting to see people's different input...
I am usually concerned with that issue on residential buildings. lots
of architects like skinny columns ! concrete is much cheaper than
steel tubes... I think I might look at the column with a P-Delta load
plus the P, and see if it can take it. Also to look at buckling...
Concrete Drop Panels
ACI has a drop panel requirement:
Section 13.3.7.2 - Projection of drop panel below the slab shall be at
least one-quarter the slab thickness beyond the drop.
???
This wording has confused me. I think however, that it means the drop
panel, to be considered a drop panel, shall be at least a 1/4 of the
slab thickness, so if I have an 8" slab, then the drop panel shall be
at least 2", giving an overall depth to the panel of 10" which
includes the slab... no???
******* ****** ******* ******** ******* ******* ******* ***