Monday, October 29, 2007

Re: slabs on grade...

Essentially, there isn't a min.
SOG isn't covered in ACI 318. It's in 360 for design, and 302 is a construction guide.
PCA printed an Industrial SOG thickness des guide.
JDCoombs

>>>
From: "David Fisher" <dfisher@fpse.com>
To: <seaint@seaint.org>
Date: 10/29/2007 10:48 AM
Subject: slabs on grade...

List:

Does anyone know where the minimum slab on grade reinf. is specified?

What we typically specify (6x6/W1.4xW1.4) doesn't of course meet 0.0018 for
a 4" or 5" slab,

But, like a contractor would say, "That's how we've been doing it for years"

TIA,