Tuesday, October 30, 2007

RE: slabs on grade...

I have never read a minimum requirement but, I have been specifying
6x6xW2.9xW2.9 for the last couple of years because I was told you can walk
on this better during construction without it all ending up on the bottom.

If I might add to the line of questioning...

ACI 302.1R recommends that wwr should be discontinuous thru joints, it also
states partial discontinuance to maintain some load transfer capacity. I
have used a detail that calls for every-other wire to be cut at joints.
Never got a complaint but is this reasonable? I am wondering what many of
you do for the joints in slabs with WWR especially if you have a PEMB FDN
with hairpins.

Mark


From: "Scott Maxwell" <smaxwell@umich.edu>
To: <seaint@seaint.org>
Subject: RE: slabs on grade...

This is a multi-part message in MIME format.

------=_NextPart_000_009A_01C81A2D.2BF0F000
Content-Type: multipart/alternative;
boundary="----=_NextPart_001_009B_01C81A2D.2BF0F000"


------=_NextPart_001_009B_01C81A2D.2BF0F000
Content-Type: text/plain;
charset="us-ascii"
Content-Transfer-Encoding: quoted-printable

David,
=20
I am not aware of any code required minimum reinforcement requirement =
for
slabs on grade in the US. The IBC does require a minimum of 3.5" slab =
in
section 1911, but places no requirements on reinforcement. Many people =
use
the minimum slab reinforcement ratios from ACI 318, but ACI 318 =
specifically
states that it does NOT apply to slabs on grade. As pointed out, the =
ACI
documents for SOGs are ACI 302 and 360, but neither are "mandatory"
documents, but rather guides or recommendations. I don't recall off the =
top
of my head if they offer recommendations on minimum reinforcement, but =
even
if they did those recommendations have no force of law. If you really =
want
to know, then say that word and I will dig them up and see if I can =
refresh
my memory.
=20
Regards,
=20
Scott
Adrian, MI


******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
*

http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org

******* ****** ****** ****** ******* ****** ****** ********