Wednesday, December 19, 2007

Re: CBC 2007 Wind Load

I think this load combination is targeted primarily for Wind + Snow
combinations. Remember the old 1/2Wind + Snow and Wind +1/2 Snow? This has
been replaced by the simpler 0.75Wind + 0.75Snow (or 0.75 Lr). For the
low-landers who do not have big snow storms, I have personally been involved
with a number of buildings where the roof drains plugged (wind borne debris)
and the roof filled with water while the wind was howling. I have also seen
several projects where roofing materials were stacked on a roof (rafter
component live load), and remained there throughout a windstorm, because the
roofers were smart enough to stay off the roof during the storm.

Dmitri Wright, PE
Cascade Engineering, Inc.
2459 SE TV Hwy, PMB #202
Hillsboro, OR 97123-7919
dmitri@cascade-structural.com
503-846-1131


>Who/what is on the roof causing live load during a wind event I ask?

******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
*

http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org

******* ****** ****** ****** ******* ****** ****** ********