I would like to ask for feedback on the design / specifying of sheathing for uplift.
For uplift on roof sheathing in HIGH WIND areas, is "Pull-through" a concern for the Plywood or OSB? For Component and Cladding loading at some of the end zones, net uplifts can exceed 100 psf (for example, ASCE 7-02, V=130 mph, Exp. C, Bldg Class. III and Zone 3).
APA provides design data for allowable stresses for spans and thicknesses of material, but for a situation where loading can be concentrated at the nail head "bearing" (kind of a reverse punching shear), are there special precautions I should warrant against? Are there some type of washer that is sometimes typically used at these locations to help "spread out" the load?
I have tried to find specific info on the Internet, without success, so I was hoping for some assistance from those who work with such high uplift pressures more frequently than I.
Thanks
Jerold Taylor PE