Saturday, May 17, 2008

RE: Alterations Chapter 34 2007 CBC

Do I have the wrong code?

3403.2.3.2 has two limits; 5% reduced strength and 10% increase of
seismic force.

A modified element is no longer an existing condition. Include in the
modification reinforcement to prevent a more than 5% reduction in
strength and to prevent more than a 10% increase of force to it and
elsewhere.
If another element does increase more than 10%, then make it part of the
new by reinforcing it also. This becomes more of a concern if the
stiffness of the first element is reduced by about 20%.

I think what might be more likely to kick in a full upgrade is when one
adds an average seismic weight to a whole floor or building. Or a change
in use.

David Merrick, SE

******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
*

http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org

******* ****** ****** ****** ******* ****** ****** ********