IIRC, the SEAOC Blue Book had commentary/language that a designer can reasonably argue the moment frame design force based on a lower R while the balance of the structure is designed for the higher R value for shetthed wood walls. Most building departments have accepted this argument before.
As for the rowhouse, if 3 stories tall, I don't think a moment frame or wood shearwall building would meet the building separation requirements at 1". Good luck.
--
David Topete, SE
On Thu, Oct 2, 2008 at 8:59 AM, Jeff Smith <jeffsmith7@comcast.net> wrote:
I am looking at the exceptions to section 12.2.3.1 page 122 ASCE 7-05 Exception 3Does exception 3 mean that for a typical wood framed three story single family dwelling with a moment frame at only the garage, the building be designed for an R of 6.5 and design just the moment frame for 3.5?Is a zero set back row house considered a "detached" dwelling, (1" between buildings)?Jeff
--