I have a 2 story steel framed building with a masonry fire separation wall.
IBC 702 definitions requires the wall to stand if the structure on either
side of the wall collapses. Ideally I would like to use the fire wall as a
shear wall for one side of the wall. I realize this may not be practical.
I'm wondering if someone has developed a detail for attaching to the wall
as a shear wall but breaking away when needed for a fire event.
I have seen someone else use a detail where they bolted an angle to the
face of the wall and welded a smooth stud to the bottom of the outstanding
leg. They then welded a horizontal plate from the steel beam that had a
hole in it for the stud to slide up and down. If the beam went down far
enough the stud pulled out of the hole. The idea is interesting, but I
think it has a flaw. If the beam is pulled horizontal, say towards the
center of collapse, it still pulls horizontally on the wall. I thought
maybe using a slot perpendicular to the wall instead of a hole, to let the
beam pull away, yet have resistance for a shear wall force, but I guess I
can't guarantee the beam would only be pulled in that direction due to a
collapse.
Can anyone describe to me a better detail?
Thanks for your help.
Rich
******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********