Monday, January 12, 2009

Re: Rho and Omega

I believe the intent is that when the overstrength factor is used in any of the applicable load combinations, you need not use Rho (+ = 1.3).  

On Mon, Jan 12, 2009 at 4:05 PM, <Tom.Hunt@fluor.com> wrote:

ASCE 7 Section 12.3.4.1 Items 5 and 6 state that the redundancy factor, rho, may be taken as 1.0 when the overstrength factor omega has been used (a slight paraphrase).  In looking closely at all the load combinations, including the ones for overstrength (i.e. collector elements, connections, etc.), I do not see any combinations where rho and omega are used together so what is the point of Items 5 and 6??

Thomas Hunt, S.E.
Fluor
------------------------------------------------------------ The information transmitted is intended only for the person  or entity to which it is addressed and may contain  proprietary, business-confidential and/or privileged material.   If you are not the intended recipient of this message you are  hereby notified that any use, review, retransmission, dissemination,  distribution, reproduction or any action taken in reliance upon  this message is prohibited. If you received this in error, please  contact the sender and delete the material from any computer.    Any views expressed in this message are those of the individual  sender and may not necessarily reflect the views of the company.   ------------------------------------------------------------ 



--
David Topete, SE