below the water table. The pool might try to float. When they are
replacing underground tanks up here (Anchorage AK, few pools) at gas
stations, they pour a slab that extends beyond the tank on all sides
that will be restrained by the earth above and prevent flotation. I
don't know how they handle flotation in the case of pools.
Thor Tandy wrote:
> I'm doing a small residential pool (about 35'x24' sloping bottom from
> 4' to 9'). It's been awhile since I last did a fluid containing
> structure. Is ACI 315 the correct standard or does anyone know an
> accessible detailing reference? The primary structural design is not
> the issue. I've usually taken care of crack mitigation and detailed
> accordingly but I might have forgotten something secondary but important.
>
> Is it common/rare to design the top edge apron as supporting the
> walls, or should I stick with cantilevered walls?
>
> Since it's in-ground, I'm assuming seismic is not an issue ...?
>
> Any other advice?
>
> TIA
>
> Thor A. Tandy P.Eng, C.Eng, Struct.Eng, MIStructE
> Victoria, BC
> Canada
>
******* ****** ******* ******** ******* ******* ******* ***