Mondo,
In the Gulf region one of your biggest problems, if you have a steel or concrete tank, is corrosion. The soils typically have very high concentrations of evaporated sea salts. Even above ground structural steel is often galvanized then epoxy painted, above ground concrete painted with siloxanes, and below grade concrete foundations are often completely "tanked" with a bithuthene.
Thomas Hunt, S.E.
Fluor
edmondo san jose <engr_mondo@yahoo.com> 01/15/2009 08:49 PM Please respond to seaint |
|
List, Any watch-its for the design of large underground potable water tank in gulf region? Tank size: length= 50m width= 100m height= 5m TIA, Mondo |
------------------------------------------------------------ The information transmitted is intended only for the person or entity to which it is addressed and may contain proprietary, business-confidential and/or privileged material. If you are not the intended recipient of this message you are hereby notified that any use, review, retransmission, dissemination, distribution, reproduction or any action taken in reliance upon this message is prohibited. If you received this in error, please contact the sender and delete the material from any computer. Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of the company. ------------------------------------------------------------