Saturday, June 27, 2009

Re: Shrinkage of Concrete Floodwall

Stan, just curious, but why are cracks a concern, whereas the
potential similar-size gap in an expansion joint isn't?

Ralph Hueston Kratz
www.rhkse.com

Sent from my iPhone 3G

On Jun 26, 2009, at 12:16 PM, Stan Caldwell <stancaldwell@gmail.com>
wrote:

> Shrinkage of concrete during curing seems to me to be one of those
> fuzzy areas of structural engineering practice. Perhaps some of you
> can help shave the fuzz.
>
> We have to design a small concrete floodwall on top of an existing
> levee. The wall will be about 300 ft. long, 12 in. thick, and 2 to
> 3 ft. tall. Joint spacing will be based on shrinkage, and joint
> width will be based on thermal expansion (101 dF in Dallas today).
> Back to the shrinkage problem, this is a flood protection wall so we
> do not want any cracks. We are thinking of 20 ft. joint spacing,
> but are having trouble justifying this choice, or any other, based
> on available literature.
>
> Any thoughts?
>
> Stan R. Caldwell, P.E.
> HALFF Associates, Inc.
> Richardson, Texas
>
>
>

******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad@seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********