List,
 
I have a stairwell, 10 ft X 18 ft(plan dimension) x 140 ft tall structure located in SDC 'D'. The columns are braced on all sides.
This is for a tall vessel 140 ft in height. & the staircase serves as the only access to reach the vessel at different heights
for the maintenance people.  The stairwell is hardly occupied, may by 1 - 5 persons at a time per day, about 1 to 5 times
per day.
 
Up to a height of about 40 ft, the stairwell is laterally tied to a piperack structure(that is non building structure, similar to buildings)
located at about 10 ft from the stairwell.  The staircase serves as an access to piperack platform also at 40 ft height.
 
I am trying to see whether OCBF fits the staircase structure  The stair structure is not a heavily occupied structure and I think
using SCBF(many details) may be too much.  But,  IBC 2006/ASCE 7-05 assigns a height of 35 ft to OCBF under 'Building' structures.  
Can you pl. look into it & tell, under which braced system, the structure falls into(OCBF or SCBF)?  
 
Thanks
 
 
Ravi Vasu
 
immediately by replying to the message and deleting it from your computer.
 

NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer.