Check out section C3.1.2 Lateral Torsional Buckling Strength from the North American Cold-Formed Steel Specification. The following sections also discuss bracing with standing seam roofing and other similar methods.
Jim Wilson, PE
Stroudsburg, PA
From: "katy6827@cox.net" <katy6827@cox.net>
To: seaint@seaint.org
Sent: Tue, November 10, 2009 7:16:04 PM
Subject: Structural Studs Allowable Bending Moment
All the information I have found on Structural (S) Stud Sections in regards to the Allowable Bending Moment has stated that the tabulated values are for continuously supported members. I am looking for information on the bending moment strength of members when they are not continuously supported. Has anyone seen this information or know where I can aquire it?
Thanks,
Katy
******* ****** ******* ******** ******* ******* ******* ***