RE: Interior wood shear wall lateral bracing

Oshin and David,

The truss bracing in this case will be a sheetrock ceiling.  It will be attached to the trusses how they typically would do it.  They would probably have blocking nailed to the top of the wall and the sheetrock would be screwed to that.  So, yes, it would fall within the length of the wall.  But the actual connection is probably a guess unless I specified it.  In the interest of time I have already resubmitted the plans with the bracing shown on the drawings.  I just wanted to know others thoughts on it because in my area I have yet to see this bracing specified, let alone installed.  It’s hard enough to get gable end bracing installed.  Thank you both for the feed back.  Although I may not be 100% convinced, it looks like I will be specifying the bracing from now on.

 

Jeff