Re: Foundation piles deviations

David,
Perhaps you can design a reinforced concrete grade beam arrangement supported by the existing piles and adding helical piles only where necessary.
Happy New Year
Irv

--- On Sun, 1/1/12, David Cohen (Baran Raviv) <dcohen@barviv.co.il> wrote:

From: David Cohen (Baran Raviv) <dcohen@barviv.co.il>
Subject: Foundation piles deviations
To: seaint@seaint.org
Date: Sunday, January 1, 2012, 8:47 AM

Engineers

I have a building in construction phase, as the designer, the contractor and the client are sending the as-made location of the foundation piles.

The piles were done by CFA Method, 70cm diameter, 15m depth.

Almost each of the pile was done in deviation from the original design location I'd designed, about 2% to 20%

Do you know a kind of rectification for this kind of installation errors, or just to execute some other ones?

Executing other ones will be very complicated; I'm looking for other smarter solutions.

Thanks.

 

David Cohen

Mobile-054-5515105

Office-03-9775278

Fax-03-9775232

www.barangroup.com



**********************************************************************

Confidentiality Message

This email message, including its attachments, is intended only for the use of the individual or entity to which it is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law. If the render of this notice is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please delete it from your system forthwith and notify us immediately. Thank you.


**********************************************************************