Tuesday, May 22, 2007

RE: Alternate Cold Joint Location

Has the contractor offered to share his cost savings with the owner?  This should help defray your costs in evaluating his proposal.

 

Bob Garner

 


From: Bill Allen [mailto:T.W.Allen@cox.net]
Sent: Tuesday, May 22, 2007 2:36 PM
To: seaint@seaint.org
Subject: Alternate Cold Joint Location

 

Dear colleagues,

 

A contractor has requested an alternate cold joint location. In the sketch found in the link below:

 

http://www.allendesigns.com/projects/20603/20603AlternateColdJoint.gif

 

Alternate A is the method shown on the approved plans.

 

Alternate B is what the contractor wants to do.

 

The dowels match the slab bars.

 

Should I have a concern about the request?

 

Regards,

 

T. William (Bill) Allen, S.E.

ALLEN DESIGNS

Consulting Structural Engineers
 
V (949) 248-8588 F(949) 209-2509