Re: Fw: roof truss daiphragm forces

No. He's full of beans.
Chuck Utzman, P.E.

Pinyon Engineering wrote:
>
>
>
> Dennis ,
>
> This is a 40x36 2-story garage with a 5:12 roof slope and 2:12
> ceiling vault with gable end balloon framed to the roof sheathing.
> They are mfg 2x light wood trusses. I talked with him an he was
> worried about the tension forces across the ridge in the truss members
> due to internal stresses caused by diaphragm action. I called out for
> 3x blocking at the ridge so both roof plywood planes could be nailed
> together.
>
> seems like this plan checker is looking too deep
>
> Thanks
>
> Tim

******* ****** ******* ******** ******* ******* ******* ***