Friday, June 12, 2009

Re: Specifications - Welding in Seismic Zone

Tom
 
Can you discuss which sections of the new AWS D1.8 would be good to copy and include in our standard drawings and specifications.
 
 
Joe Venuti
Johnson & Nielsen Associates
Palm Springs, CA
 
In a message dated 6/12/2009 2:28:03 P.M. Pacific Daylight Time, Tom.Hunt@fluor.com writes:

Refugio,

The first official release of AWS D1.8 was issued too late for incorporation into our current codes such as IBC, AISC, etc.  So unless your local jurisdiction has invoked it or the Engineer of Record has included it in the project requirements there is no regulation that says you have to use AWS D1.8.  That said, I would suggest cutting and pasting a lot of the good words from AWS D1.8 onto your standard drawings and/or specifications.  This now gets even worse as the 2009 IBC will still references the 2005 AISC Seismic Provisions so AWS D1.8 will not be officially be referenced until the 2010 AISC Seismic Provisions.  IBC is still on a 3 year cycle whereas AISC has moved to a 5 year cycle.

Thomas Hunt, S.E.
Fluor



Refugio Rochin <refugio.rock.hill@gmail.com>
06/12/2009 01:50 PM
Please respond to seaint
To
seaint@seaint.org
cc
Subject
Specifications - Welding in Seismic Zone





If a project is in high seismic zone, by that nature is welding in
that zone required to meet AWS D1.8?
I think a better question is, when is AWS D1.8 required?
Unfortunately I do not have the AWS D1.8 nor D1.1 to reference D1.8 use.

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad@seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********

------------------------------------------------------------ The information transmitted is intended only for the person or entity to which it is addressed and may contain proprietary, business-confidential and/or privileged material. If you are not the intended recipient of this message you are hereby notified that any use, review, retransmission, dissemination, distribution, reproduction or any action taken in reliance upon this message is prohibited. If you received this in error, please contact the sender and delete the material from any computer.  Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of the company. ------------------------------------------------------------